List 50: Rectifier Module (PCU)
Features
Provides one (1) Model R24-2500, Spec. No. 1R242500, Rectifier
Module (PCU).
Refer to Power Data Sheet
PD588705100/PD588705101/PD588705102/PD588705103/
PD588705104 for more information.
Restrictions
For use in Spec. No. 588705100, 588705101, 588705102, 588705103, or 588705104 Module Mounting
Assemblies.
Ordering Notes
1) Order as required.
List 60: DC-DC Converter Option Interface Component Kit
Features
Provides components to add DC-DC Converter capability to one (1)
8-position Module Mounting Shelf in a Module Mounting Assembly.
With one (1) List 60 installed, the four middle mounting positions in an
8-position Module Mounting Shelf in the Module Mounting Assembly
will accept DC-DC Converters or Rectifier Modules (PCUs).
Includes cables for connection of converter output to a dual voltage
bus distribution panel assembly.
Restrictions
MUST be factory installed only.
CANNOT be used in Supplemental Bays.
Must be used in conjunction with a dual voltage bus distribution panel
assembly (List
JA, JB, JC, JD, KA, LB, or LC). Up to two (2) converter kits
can be used with a List JA, JB, JC, JD, LB, or LC. Up to four (4) converter
kits can be used with a List KA.
Total rectifier output power available for customer loads is reduced by the input power of each DC-DC
Converter Module installed.
Ordering Notes
1) Order one (1) List 60 (DC-DC Converter Option Kit) for each 8-position Module Mounting Shelf in which
DC-DC Converters are required (see restrictions above). Note that some Module Mounting Assemblies
consist of multiple 8-position mounting shelves. The kit permits the middle four (4) positions in an
8-position Module Mounting Shelf to accept DC-DC Converter Modules or Rectifier Modules (PCUs). List
60 is factory installed within the 8-position Module Mounting Shelf. Multiple List 60 kits will be installed
starting with bottom 8-position Module Mounting Shelf in the Module Mounting Assembly and working up.
Note that Supplemental Bays CANNOT have Converter Modules.
2) Order up to four (4) converter modules (
List 62) for each List 60 ordered.