13) Order as required additional options per Lists 29, 71, and 93.
14) Order as required any additional accessories described under
ACCESSORY DESCRIPTIONS.
List 2: Supplemental Bay Common Equipment (Power and Distribution)
(located next to Main Bay)
Features
Provides common equipment for one bussed “power and distribution” bay rated for up to 2000 amperes of
distribution. Includes interbay power busbars and communications cabling.
Mounts to either left or right side of a
List 1 Main Bay.
Accepts one (1) Distribution Cabinet (options are 3-Row or 4-Row cabinet).
Accepts one (1) Module Mounting Assembly. The Module Mounting Assembly can consist of one (1), two
(2), three (3), or four (4) factory interconnected 8-position Module Mounting Shelves. Each Module
Mounting Shelf in a Module Mounting Assembly provides eight (8) mounting positions for Rectifier
Modules (PCUs).
or
Can be configured for “distribution only” (no Module Mounting Assembly).
Restrictions
Order maximum of one (1) List 2 or
List 5 per Power System.
Cannot be used when List 5 is ordered. Order List 2 or List 5, not both.
Supplemental Bays DO NOT accept Converter Modules. DO NOT order List
60 or 62 for Supplemental Bays.
List 2 Supplemental Bay DOES NOT accept List
21 or 22 Distribution Cabinet
(List 21 and 22 are not provided with connection points for interbay busbars.)
Rear access is required for installation of inter-bay busbars.
Ordering Notes
1) Order a relay rack per '
Relay Racks' under ACCESSORY DESCRIPTIONS. If required, order Relay Rack
Transition Plates per '
Transition Plates to Mount Relay Rack P/N 543156 on Top of GNB Absolyte IIP
Batteries' under ACCESSORY DESCRIPTIONS. Relay rack must be same height as relay rack ordered
for
List 1. A ship loose option is available, as described in 'Relay Racks' under ACCESSORY
DESCRIPTIONS.
2) Order one (1) List
23 or 24 Distribution Cabinet.
3) Order up to four (4) Distribution Bus Panels as required per '
Distribution Bus Arrangements' and the
capacity of the Distribution Cabinet ordered.
4) Order one (1) List
30 (interface components for one (1) Module Mounting Assembly). Order a Module
Mounting Assembly per PD588705101/PD588705102/PD588705103/PD58805104. List 30 is factory
connected to the Module Mounting Assembly ordered.
or
Order Supplemental Bay 'Distribution Only' option per List
4.
5) Order Rectifier Modules (PCUs) per List
50 as required.
6) Order one (1) Module Mounting Position Blank Cover Panel,
Part No. 540959, for each empty module
mounting position in the system.
7) Order fuses and/or circuit breakers, as required, per '
Distribution Devices' under ACCESSORY
DESCRIPTIONS.
8) Order input and load distribution lugs, as required, per '
Wiring Components' under ACCESSORY
DESCRIPTIONS.