Emerson SAG581126000 Power Supply User Manual


 
SAG581126000 System Application Guide
Issue AD, November 23, 2009 Spec. No. 581126000 (Model 700
NVBA)
Page 106 of 123
This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy
Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.
SYSTEM LOAD MENU
86
SYSLOAD** #####A
87
MEASUREMENT MENU
88
NORMAL DISPLAY
PCU LOAD MENU
89
PCU** LOAD #####A
90
MEASUREMENT MENU
91
NORMAL DISPLAY
SUBSYSTEM LOAD MENU
92 SUBLOAD** #####A
93
MEASUREMENT MENU
94
NORMAL DISPLAY
BATTERY LOAD MENU
94A
94B
BAT** CHG #####A
BAT** DIS #####A
94C
MEASUREMENT MENU
NORMAL DISPLAY
SYSTEM ADJUSTMENT MENU
95
FLOAT = ###.##V
96
TEST/EQ = ###.##V
97
SET HVS = ###.##V
99
CURR LIM = ####A
CURRLIM = #####MAX
99A
BATTLIM DISABLED
BATTLIM = #####A
100
100% CURR: ####A
101
ADJUSTMENT MENU
102
NORMAL DISPLAY
ALARM ADJUSTMENT MENU
FUNCTION MENU
MEASUREMENT MENU
41
MEASUREMENT MENU
42
SET TEST/EQ MODE
SET FLOAT MODE
TestEq Switch On
43
ADJUSTMENT MENU
44
CONFIGURE MENU
45
CALIBRATION MENU
46
NORMAL DISPLAY
ADJUSTMENT MENU
LVD ADJUSTMENT MENU
68
ADJUST SYSTEM
69
ADJUST ALARMS
70
ADJUST LVDs
71
FUNCTION MENU
72
NORMAL DISPLAY
CONFIGURE MENU
114
LVD ** = ##.#V
115
LV RECON = ##.#V
MANUAL RECONNECT
116
ADJUSTMENT MENU
117
NORMAL DISPLAY
INVENTORY MENU
CALIBRATION MENU
PCU ENABLE MENU
130
PCU** ON:SET OFF
PCU** OFF:SET ON
Energy Mgmt. On
131
CONFIGURE MENU
132
NORMAL DISPLAY
118
PCU** TYPE ####A
NO PCUs FOUND
PCU** TYPE ####+
119
VACANT ****A= ##
****A PLACES= ##
120
SHUNT** TYPE SYS
SHUNT** TYPE SUB
SHUNT** TYPE BAT
NO SHUNTS FOUND
121
LVD** INSTALLED
NO LVDs FOUND
121A
122
SUBSYS INSTALLED
NO SUBSYS FOUND
123
REMOTE INSTALLED
REMOTE ACTIVE
NO REMOTE FOUND
124
UPDATE INVENTORY
PLEASE WAIT...
REPLACE ** PCUs?
125
CONFIGURE MENU
126
NORMAL DISPLAY
127
SPEC NO. #########
128
MCA SWV ########
129
REM SWV ########
ANALOG TC FOUND
NO TEMP SENSORS
T SENSOR** INST
103
104
105
106
SYS 50% = ###.##V
VERYLOVOLT = ###.##
14
107
SYSCURR = #####A
108
SUB HV = ###.##V
109
SUB LV = ###.##V
110
SUBCURR = #####A
110A
BAT CHG = #####A
111
112
ADJUSTMENT MENU
113
NORMAL DISPLAY
HI TEMP** = ###°C
HI TEMP** IS OFF
LO TEMP** = ###°C
LO TEMP** IS OFF
61
SYSTEM ###.##VDC
62
SYS LOAD #####A
63
PCU LOAD #####A
64
SUBSYS ###.##VDC
65
SUB LOAD #####A
65A
BAT CHG #####A
BAT CHGCL #####A
BAT DIS #####A
66
FUNCTION MENU
67
NORMAL DISPLAY
65B
T SENSOR** ###°C
73
VERIFY INVENTORY
73C
DISPLAY ROLL OFF
DISPLAY ROLL ON
74
SET PCU ON / OFF
74A
LO SPEED FAN OFF
LO SPEED FAN ON
75
NAG MINUTES = ##
AUDIBLE NAG OFF
76
TEST/EQ HRS = ##
TEST/EQ MAN STOP
END TEQ ##.##HRS
76A
AUTO EQ DISABLED
AUTO EQ MUL = ##
END AUTO ##.## HR
77
RELAYTEST = ###SEC
78
FUNCTION MENU
79
NORMAL DISPLAY
80
CAL SYS = ###.##V
81
CAL SUB = ###.##V
82
RESTORE MFG CAL
83
ANALOG TC OFF
TC CAL = ##.##V
TempCmp Hardware
84
FUNCTION MENU
85
NORMAL DISPLAY
DIGITAL TC OFF
SLOPE = .###V/°C
TempCmp Hardware
MAX W/T = ##.##V
MIN W/T = ##.##V
N
ET
S
URE™
MCA Menu Tree
(Sheet 2 of 2)
A
from Sheet 1
110B
110C
83A
83B
83C
77A
SET SPANISH TEXT
TEST RELAYS
TESTING RELAY #
Alarm(s) Active
SYS HV1 = ###.##V
HI FLOAT = ###.##V
15
SYS HV2 = ###.##V
HI VOLTAGE = ###.##V
15
SYS BOD = ###.##V
LO FLOAT = ###.##V
15
LO VOLTAGE = ###.##V
15
73A
SHARE ALARM OFF
SHARE ALARM ON
83D
TCOMP ON SENSOR1
TCOMP ON AVERAGE
TCOMP ON HIGHEST
EMERG STOP OFF
EMERG STOP ON
REMOTE HVS OFF
REMOTE HVS ON
73B
73D