195
PRIMERGY RX200 S2 User’s Guide
Installing Internal Options
7
5 Install a new internal hard disk unit or a dummy unit.
"7.7.3 How to Install an Internal Hard Disk Unit" (pg.193)
■ Replacing the Failed Internal Hard Disk Unit
When an array system (RAID1) is configured with the onboard SCSI array controller on this server, a
failed hard disk unit can be replaced and restoration can be performed without turning off the server and
peripheral devices (hot swappable/hot pluggable).
For details on the array system, refer to "Onboard SCSI RAID User's Guide".
The following is an outline of the procedure for replacing a failed internal hard disk unit.
1 Check the hard disk unit failure LED on each bay.
2 Touch a metal part of the server to discharge static electricity.
3 Move the handle on the failed hard disk unit up and pull it a little towards you.
4 Wait for approximately 60 seconds (until the hard disk stops rotating) and pull
out the failed hard disk unit.
5 Install a new internal hard disk unit.
6 Rebuild the new internal hard disk unit.
For the rebuild procedure, refer to "Onboard SCSI RAID User's Guide".