Fujitsu RX200 S2 Server User Manual


 
256
Chapter 9 Operation and Maintenance
Memory Redundancy Feature could
not configure the Spare DIMMs
This message appears when the user attempts to enable the hot spare
memory function while the capacity differs between the paired memory
modules or memory modules are not installed in a pair. Check the
capacity of all installed memory modules. If the message still appears,
the baseboard must be replaced. Contact an office listed in the "Contact
Information" of the "Start Guide".
"7.4 Installing Memory Modules" (pg.174)
Non Fujitsu Siemens Memory Module
detected - Warranty restricted!
The memory is abnormal. Check to see that the jumper pin settings or
BIOS Setup Utility settings are correct. If the message still appears, the
baseboard must be replaced. Contact an office listed in the "Contact
Information" of the "Start Guide".
"Chapter 8 Hardware Configuration/Utilities" (pg.205)
Application CPU timeout error Power off the server and turn it back on. If the message still appears,
check the error log and replace the CPU. If the message still appears, the
baseboard must be replaced. Contact an office listed in the "Contact
Information" of the "Start Guide".
"7.3 Installing a CPU" (pg.169)
System battery is dead - Replace and
run SETUP
The battery is abnormal. Contact an office listed in the "Contact
Information" of the "Start Guide".
System CMOS checksum bad -
Default configuration used
Correct the changed settings with the BIOS Setup Utility or restore the
settings at the time of purchase. If the message still appears, the
baseboard must be replaced. Contact an office listed in the "Contact
Information" of the "Start Guide".
System timer error Power off the server and turn it back on. If the message still appears, the
baseboard must be replaced. Contact an office listed in the "Contact
Information" of the "Start Guide".
Real time clock error
Check the date and time settings on the "8.2.2 Main Menu" (pg.211)
of the BIOS Setup Utility. If the message still appears, the baseboard
must be replaced. Contact an office listed in the "Contact Information"
of the "Start Guide".
Check date and time settings
CPU had been changed - Run SETUP
Check that the correct CPUs are installed. If the same message appears
again, change [Reset Configuration Data] on the "8.2.5 Advanced
Menu" (pg.215) to [Yes] in the BIOS Setup Utility. If the message still
appears, contact an office listed in the "Contact Information" of the
"Start Guide".
CPU mismatch detected
Check that the correct CPUs are installed. If so, update the BIOS. If the
same message appears again, change [Reset Configuration Data] on the
"8.2.5 Advanced Menu" (pg.215) to [Yes] in the BIOS Setup Utility. If
the message still appears, contact an office listed in the "Contact
Information" of the "Start Guide".
Baseboard Management Controller
Error
Turn the server off and unplug the power cables from the server. Turn
the server back on. If the message still appears, the baseboard must be
replaced. Contact an office listed in the "Contact Information" of the
"Start Guide".
Diskette drive A error
Check the settings on the "8.2.2 Main Menu" (pg.211) of the BIOS
Setup Utility. Check to see whether the floppy disk drive cable is
connected properly. If the message still appears, contact an office listed
in the "Contact Information" of the "Start Guide".
Incorrect Drive A type - run SETUP
CPU runtime error(IERR#) detected Check the system event logs. If the message still appears, contact an
office listed in the "Contact Information" of the "Start Guide".
table: List of POST Error Messages
Message Description