8.2.12 IPMI Submenu
Appears when [IPMI] is selected from the [Server] menu.
Configures the Baseboard Management Controller (BMC).
table: Items on the IPMI Submenu
Item Setting Description
IPMI Specification Version - Displays the IPMI Specification version.
BMC Firmware - Displays the BMC Firmware version.
Clear System Event Log Disabled (at the time of
purchase)
Enabled
Deletes the logs stored in the system event log.
Event Log Full Mode Overwrite (at the time of
purchase)
Maintain
Set the operation to be performed when the system
event log becomes full.
Overwrite: Logs are overwritten in old to new
order.
Maintain: Existing logs are maintained. No new
logs are recorded.
Note:
Before changing the setting for this item, be
sure to use [Clear System Event Log] to
delete the system event log.
Existing Event Log number - Displays the number of recorded logs.
Remaining Event Log
number
- Displays the number of logs that can be recorded.
System Event Log [Enter] Displays the contents of the system event log.
For details on contents, refer to "9.3 System Event
Log" (pg.267).
System Event Log
(list mode)
[Enter] Lists the contents of the system event log.
For details on contents, refer to "9.3 System Event
Log" (pg.267).
Real-time Sensor Data [Enter] Displays temperature and voltage sensor data.
PhoenixBIOS Setup Utility
Item Specific Help
IPMI Specification Version n.n
BMC Firmware n.nn.nnnnnnnn
Clear System Event Log [Disabled]
Event Log Full Mode [Overwrite]
Existing Event Log number nnn
Remaining Event Log number nnn
System Event Log
System Event Log (list mode)
Real-time Sensor Data