Fujitsu RX200 S2 Server User Manual


 
287
PRIMERGY RX200 S2 User’s Guide
9
Operation and Maintenance
9.10 Maintenance & Notes
This section explains the details of the maintenance & Notes.
9.10.1 Hard disk failure is detected
If hard disk failure is detected during POST, the RX200 S2 on-board SCSI array controller stops with
the following message.
If the controller stops with this message, insert the floppy disk "OnBoard RAID Utility" into the floppy
disk drive of the system, and press the [Ctrl] key and [A] key at once to start up the system from the
floppy disk. The utility automatically starts up. The following message appears on the utility.
As shown here, if the message "Fatal Error happened. Please call support engineer." appears, do not
start up the system. Please contact the maintenance person and system administrator.
Warning!: The array is degraded. Press [Ctrl] [A] to continue after
insert Floppy Disk.
Background command progress status for controller 0...
IR Volume 1
Current operation : None
Volume ID : 0
Volume status : Enabled
Volume state : Degraded
Physical disk I/Os : Not quiesced
curState: 1 prvState: 0
Previous Physical Disk States:
ID0 : Failed ID1 : Failed
Current Physical Disk States:
ID0 : Online ID1: Failed
Fatal ERROR happened. Please call support engineer
Background command progress status for controller 0...
IR Volume 1
Current operation : None
Volume ID : 0
Volume status : Enabled
Volume state : Degraded
Physical disk I/Os : Not quiesced
curState: 1 prvState: 3
Previous Physical Disk States:
ID0 : Online ID1 : Failed
Current Physical Disk States:
ID0 : Online ID1: Failed
OK. You can boot system.
Please check HDD status after boot