Graco 312353B Network Router User Manual


 
System Administrator Screens
312353B 33
System Configuration ______________________________________
There are three sections of the System Configuration screen: General system-wide default settings, transceiver set-
tings, and PC client settings (F
IG. 63).
The System Configuration setup must be performed prior to defining all other Matrix system setup parame-
ters.
To change any of the settings listed for system configu-
ration, click Modify.
Security Level (Global Setting)
The security level is the global security setting for all
meters in the system, The default is System Monitoring.
PIN code and Parts Room Authorization Security are
other options on the pull down menu. This security
choice can be changed on a meter-to-meter basis if
desired (F
IG. 64).
1. Click Security Level Drop Down Box and select
from the list.
System Monitoring - anyone can dispense oil, but
the dispense information will be communicated to
the PC.
PIN Code Required - the operator must enter a
user-specific 4-digit numeric code into the meter to
have authorization to dispense.
Parts Room Authorization - the operator selects
authorization to dispense at the meter. This requires
someone in the Parts Room to authorize the dis-
pense at the Matrix PC.
System Emergency Code (FIG. 64)
The System Emergency Code is used to bypass PIN
Code or Parts Room Authorization security features
should the communication link to the Matrix PC stop (i.e.
computer failure, power outage).
2. Type in a four digit system emergency code number.
This number is used at the meter to override all meter
programming should there be a loss of RF signal.
This allows the operator to continue dispensing fluids
even though the meter is not receiving an RF signal.
If the system emergency code is used to over-
ride the meter program, the meter must be pro-
grammed again using the Matrix PC software
once the RF signal has been restored.
F
IG. 63 System Configuration Screen