Graco 312353B Network Router User Manual


 
System Administrator Screens
312353B 41
Tank Shape Screen
Vertical Tank Geometry (FIG. 75)
Vertical tanks use the tank capacity to calculate tank vol-
ume. Obround and cylindrical tanks use the tank dimen-
sions to calculate tank volume.
Verifying Capacity for Obround and Cylindrical
Tanks (F
IG. 76 and FIG. 77)
After the obround or cylindrical tank setup information
has been completed, it may be necessary to modify the
tank manufacture’s published gal/liter capacity that was
entered in F
IG. 74, (page 40). (In some cases the actual
volume of the tank may exceed the manufacture’s pub-
lished capacity.) To verify this, once the TLM has been
programmed:
1. Stand the TLM upright on a flat smooth surface,
press the blue button and record the volume. The
volume shown on the PC tank setting screen should
match the volume initially entered. If it does nothing
further needs to be done.
2. If the reading does not match, modify the tank
capacity in F
IG. 74, (page 40) to match the TLM
reading taken on the flat smooth surface.
Vertical Tank
F
IG. 75 Vertical Tank
Obround Tank
F
IG. 76 Obround Tank
Cylindrical Tank
F
IG. 77 Cylindrical Tank