HP (Hewlett-Packard) 2500 Switch User Manual


 
236
Software Fixes
Release F.02.12
Fixed in release F.02.12
Monitoring Port — When a config file containing a Monitoring Port configuration is loaded
onto the switch via TFTP or XModem, the Monitoring Port feature does not work properly.
Release F.02.13
Fixed in release F.02.13
Monitoring Port — Monitoring Port configuration changes made within a particular switch
interface (e.g., Web-browser interface), are not correctly displayed within the other switch
interfaces (e.g., CLI and Menu).
Release F.04.01 (Beta Release Only)
Fixed in release F.04.01
CLI — The response to an incomplete trunk configuration command did not produce the
proper message "Incomplete input: Trunk."
CLI — The crash history is lost after the "reload" command is performed from the CLI.
Crash — A transceiver hot-swap may cause the switch to crash with a message similar to:
-> Software exception at woodyDma_rev.c154 -- in 'eDrv'.
Crash — A transceiver hot-swap may cause the switch to crash with a message similar to:
-> Software exception in ISR at buffers.c:1627.
Crash — The switch may crash with a message similar to:
-> Software exception at woodyDma_recv.c:154 -- in 'eDrv'.
This crash may occur if both the following conditions exist:
a. The "reload" CLI command is issued; and
b. A 100/1000-T transceiver is installed
Flow Control — Changing Flow Control setting on a port is not reflected in Auto-
negotiation's advertised capability.
IGMP — Interoperability issues with some Cisco devices cause IGMP groups to be aged out
of the switch's IGMP tables prematurely.
Menu/Web-Browser Interface — Display of mirror port configuration is inconsistent
between menu and WEB interface.