Software Fixes
Release F.04.08
Fixed in release F.04.08
Modification of Lab troubleshooting commands.
Release F.04.09 (Beta Release Only)
Fixed in release F.04.09
Agent Hang — Agent processes (such as console, telnet, STP, ping, etc.) may stop
functioning when the IGMP querier function is disabled, and then re-enabled, on a VLAN that
does not have an IP address configured.
Agent Hang — Agent processes (such as console, telnet, STP, ping, etc.) may stop
functioning. This agent hang has been associated with the CERT SNMPv1 "encoding" test
#1150.
Agent Hang — Agent processes (such as console, telnet, STP, ping, etc.) may stop
functioning. This agent hang has been associated with the X2 SSH utility.
CLI — When reaching the inactivity timeout expiration after typing the CLI command
"enable" in a telnet session at operator mode, the text in the CLI prompt may get corrupted
with text similar to gfs_alp_104Null Varbind.
Crash — When hot-swapping transceivers multiple times, the switch may crash with a
message similar to:
-> Software exception at port_sm.c:378 in -- 'mPmSlvCtrl'
STP/RSTP — Port path cost is reset even though path cost is configured for "Auto".
Release F.05.05 (Beta Release Only)
Time Zone Issue
Starting with the F.05.xx version of the switch software, the method of configuring the Time Zone
for TimeP or SNTP configuration has been updated. Previous switch software, for all ProCurve
switches, used positive time offset values for time zones that are West of GMT and negative values
for time zones that are East of GMT. The standards indicate that time zones West of GMT should be
designated by negative offset values, and time zones East of GMT by positive values. Software version
F. 05 .xx updates this configuration method, but if you use the same values for indicating time zones
as you did for previous ProCurve switches, the time will be set incorrectly on your ProCurve Switches
2512 and 2524. For example, for previous ProCurve switches, the US Pacific time zone was configured
by entering +480. With software version F.05.xx, the US Pacific time zone must now be configured
by entering -480.