Intel SR6850HW4 Server User Manual


 
Intel® Server Platform SR6850HW4 TPS System Overview
Revision 1.0
Intel order number D23151-001
21
2.10 Specifications
2.10.1 Environmental Specifications Summary
The Server Platform SR6850HW4 will be tested to the environmental specifications as indicated
in Table 5.
Table 5. Environmental Specifications Summary
Environment Specification
Temperature operating 10°C to 35°C 50°F to 95°F
Temperature non-operating -40°C to 70°C -40°F to 158°F
Altitude -30 to 1,500 m -100 to 5,000 ft
Humidity non-operating 95%, non-condensing at temperatures of 25°C (77°F) to 30°C (86°F)
Vibration non-operating 2.2 Grms, 10 minutes per axis on each of the three axes
Shock operating Half-sine 2 G, 11 ms pulse, 100 pulses in each direction, on each of the three axes
Shock non-operating Trapezoidal, 25 G, two drops on each of six faces
V : 175 inches/sec on bottom face drop, 90 inches/sec on other 5 faces
Safety UL60 950, CSA60 950, AS/NZS 3562, GB4943-1995, EN60 950 and 73/23/EEC, IEC 60
950, EMKO-TSE (74-SEC) 207/94, GOST-R 50377-92
Emissions Certified to FCC Class A; tested to CISPR 22 Class A, EN 55022 Class A and
89/336/EEC, VCCI Class A, AS/NZS 3548 Class A, ICES-003 Class A, GB9254-1998,
MIC Notice 1997-42 Class A, GOST-R 29216-91 Class A, BSMI CNS13438
Immunity Verified to comply with EN55024, CISPR 24, GB9254-1998, MIC Notice 1997-41,
GOST-R 50628-95
Electrostatic discharge Tested to ESD levels up to 15 kilovolts (kV) air discharge and up to 8 kV contact
discharge without physical damage
Acoustic Sound pressure: < 55 dBA at ambient temperature < 23° C measured at bystander, floor
standing position
Sound power: < 7.0 BA at ambient temperature < 23° C measured using the Dome
Method
GOST MsanPiN 001-96
See Chapter 10 for more information on environmental specifications.