National Instruments 6023E Switch User Manual


 
Appendix C Common Questions
6023E/6024E/6025E User Manual C-4 ni.com
24-bit counters (unlike the 16-bit counters on devices without the
DAQ-STC).
If you are using the NI-DAQ language interface or LabWindows/CVI, the
answer is no, the counter/timer applications that you wrote previously will
not work with the DAQ-STC. You must use the GPCTR functions; ICTR
and CTR functions will not work with the DAQ-STC. The GPCTR
functions have the same capabilities as the ICTR and CTR functions, plus
more, but you must rewrite the application with the GPCTR function calls.
I amusing one ofthe general-purposecounter/timers on mydevice, but
I do not see the counter/timer output on the I/O connector. What am I
doing wrong?
If you are using the NI-DAQ language interface or LabWindows/CVI, you
must configure the output line to output the signal to the I/O connector. Use
the
Select_Signal
call in NI-DAQ to configure the output line. By
default, all timing I/O lines except EXTSTROBE* are high impedance.
What are the PFIs and how do I configure these lines?
PFIs are programmable function inputs. These lines serve as connections to
virtually all internal timing signals. If you are using the NI-DAQ language
interface or LabWindows/CVI, use the
Select_Signal
function to route
internal signals to the I/O connector, route external signals to internal
timing sources, or tie internal timing signals together.
If you are using NI-DAQ with LabVIEW and you want to connect external
signal sources to the PFI lines, you can use AI Clock Config, AI Trigger
Config, AO Clock Config, AO Trigger and Gate Config, CTR Mode
Config, and CTR Pulse Config advanced level VIs to indicate which
function the connected signal serves. Use the Route Signal VI to enable the
PFI lines to output internal signals.
Caution
If you enable a PFI line for output, do not connect any external signal source to it;
if you do, you can damage the device, the computer, and the connected equipment.
What are the power-on states of the PFI and DIO lines on the I/O
connector?
At system power-on and reset, both the PFI and DIO lines are set to high
impedance by the hardware. This means that the device circuitry is not
actively driving the output eitherhigh or low. However, these lines can have
pull-up or pull-down resistorsconnected to themas shown in Table 4-3, I/O
Signal Summary. These resistors weakly pull the output to either a logic
high or logic low state. For example, DIO(0) is in the high impedance state