National Instruments 6023E Switch User Manual


 
Chapter 4 Signal Connections
© National Instruments Corporation 4-27 6023E/6024E/6025E User Manual
Mode 1 Input Timing
Timing specifications for an input transfer in mode 1 are shown in
Figure 4-13.
Figure 4-13. Timing Specifications for Mode 1 Input Transfer
Name Description Minimum Maximum
T1
STB* Pulse Width
100
T2
STB* = 0 to IBF = 1
150
T3
Data before STB* = 1
20
T4
STB*=1toINTR=1
150
T5
Data after STB* = 1
50
T6
RD*=0toINTR=0
200
T7
RD*=1toIBF=0
150
All timing values are in nanoseconds.
DATA
RD *
INTR
IBF
STB *
T1
T2
T4
T7
T6
T3
T5