149
The camera image is dim. Dust may be sticking on the camera
lens.
Remove the dust from the camera lens.
The camera’s lens focus may not be
proper.
Press the FOCUS NEAR/ FAR buttons to
adjust the lens focus. If the camera sup-
ports auto focus, press these buttons
simultaneously. The lens focus can be
adjusted automatically.
The camera’s cable compensation set-
ting may not be proper.
Open 730 COMPENSATION/VD2/DATA
(refer to p. 74) or the Cable Compensa-
tion/VD2 window (refer to p. 94) to con-
firm the setting.
The camera is not operable. The camera may not have been select-
ed.
Select the camera again. (Refer to p.
107.)
The camera may not support the function
you try to execute.
Confirm whether the camera supports
the function. (Refer to the camera's oper-
ating instructions.)
The camera's cable setting may wrong. Open 730 COMPENSATION/VD2/DATA
(refer to p. 74) or the Cable
Compensation/VD2/DATA (refer to p. 94)
window to confirm the setting. If the cam-
era’s DATA is set to OFF, the cameras
will not be operable.
The data port setting may wrong. Open the Data Port window (refer to p.
96) and confirm the setting.
When the BUSY indicator is lighting on
the system controller, a higher-priority
operator has selected the camera.
• Select another camera.
• Wait until a higher-priority operator fin-
ishes controlling the camera.
While the PROHIBITED indicator is light-
ing on the system controller, you are pro-
hibited to control the camera.
Open the Operator Registration window
(refer to p. 90) and reconfigure the set-
ting.
OSD items (Clock, Camera title, Monitor
status, Event) overlap one another.
• Turn off an overlapping item. (Refer to
p. 115.)
• Move OSD items. (Refer to p. 115.)
• Change the area title display position
through the camera’s setup menu.
(Refer to the camera’s operating
instructions.)
Tour/group sequence is not activated. The tour/group sequence setting may be
wrong.
Open 300 SEQUENCE (refer to p. 66),
the Tour Sequence (refer to p. 84) or
Group Sequence (refer to p. 85) window
and reconfigure the setting.
The setting has not been put from the PC
to the unit.
Put the file to the unit again after the con-
figuration. (Refer to p. 83 Put a file to
SX150A.)
When the PROHIBITED indicator is light-
ing on the system controller, you are pro-
hibited to control the camera.
Open 800 OPERATOR REGISTRATION
(refer to p. 76) or the Operator
Registration window (refer to p. 90) and
reconfigure the setting.
Problem Check item Remedy