Panasonic WJ-SX150A Switch User Manual


 
99
Secret View: Select the desired setting by clicking on
the drop-down menu.
ON: The adjoining drop-down menu becomes also
active so that you can designate the desired
monitor (MON 1 to 4) for the secret view func-
tion. If you designate MON 1 in the drop-down
menu, black image will be displayed in a seg-
ment of multiscreen monitor, instead of the spot
image of camera channel activated in MON 1.
OFF: Secret view function is unavailable.
The factory default setting is OFF.
Sequence Mode: Select the sequence type by clicking
on the radio button.
Quad: Multiplexer sequence is activated. The moni-
tor display will be changed as 4A 4B 4C
4D.
3+1: Images are displayed in 4 multiscreens, and
the images of Camera 4 to 16 are displayed in
the sequence mode, at the right bottom of the
monitor. The images of Camera 1 to 3 are fixed.
(Refer to the left-side illustration in p. 20.)
8+1: Images are displayed in 9 multiscreens, and
the images of Camera 9 to 16 are displayed in
the sequence mode, at the right bottom of the
monitor. The images of Camera 1 to 8 are fixed.
(Refer to the right-side illustration in p. 20.)
The factory default setting is Quad.
Dwell: The dwell time of the selected sequence
mode is selectable. 2S to 30S is available.
The factory default setting is 2S.
REC OUT Group
Title Display: Select the desired setting by clicking on
the drop-down menu.
ON: The camera title is displayed on the recorded
image.
OFF: The camera title is not displayed on the
recorded image.
The factory default setting is ON.
Clock Display: Select the desired setting by clicking on
the drop-down menu.
ON: The date and time are displayed on the record-
ed image.
OFF: The date and time are not displayed on the
recorded image.
The factory default setting is ON.
Normal Group
REC Mode: Select the desired setting by clicking on
the radio button.
EXT: Select this to gen-lock the unit during the nor-
mal recording.
INT: Select this if the asynchronous unit is connect-
ed to the unit. When it is activated, the drop-
down menu becomes also active so that you
can select the desired normal recording rate.
002, 004 to 255 (field) are selectable.
The factory default setting is EXT.
Alarm Group
REC Mode: Select the desired setting by clicking on
the radio button.
EXT: Select this to gen-lock the unit during the
alarm recording.
INT: Select this if the asynchronous unit is connect-
ed to the unit. When it is activated, the drop-
down menu becomes also active so that you
can select the desired normal recording rate.
002, 004 to 128 (field) are selectable.
The factory default setting is EXT.
DYNAMIC REC: Select the desired setting by clicking
on the drop-down menu.
ALM-PRI: Select this to give recording priority to
the camera channel with the alarm input.
ALM-ONLY: Select this to record the images from
the alarm-associated camera channel.
GROUP: Select this to give recording priority to a
group of up to 4 camera channels associated to
the alarm input. When you select this, the Group
Setting button becomes active. By pressing the
button, the Mux Alarm Group window will be
displayed so that you can configure the Group
1 to 16 parameters. (Refer to p. 100 Mux Alarm
Group.)
OFF: Select this to deactivate the alarm priority
mode.
The factory default setting is OFF.
System Group
Camera SW Loss: Select the desired setting by click-
ing on the drop-down menu.
ON: CAM SW LOSS will blink on the associated
monitor when loss of the camera switching
pulse is detected.
OFF: CAM SW LOSS will not appear on the moni-
tor.
The factory default setting is ON.
Dummy Black: Select the desired setting by clicking
on the drop-down menu.
ON: The black image will be displayed for a camera
channel that is not connected to the camera.
OFF: The camera channel will be skipped in the
sequence/spot mode.