41
● To Record the Camera Images in Maximum
Recording Rate
The following is the description of the connection between a
recorder and this unit for the maximum-rate recording.
1. Set the unit address of the recorder to 1. Then, set the
recorder’s CAMERA GENLOCK to ON in its SETUP
MENU. (Refer to the recorder's operating instructions.)
2. Connect the unit’s CAM OUT 1 to 16 connectors to the
recorder’s VIDEO IN 1 to 16 connectors with a coaxial
cable.
3. Connect the unit’s EXT IN connector to the recorder’s
GENLOCK OUT connector with a coaxial cable.
4. Connect the unit’s DATA HDR connector to the
recorder’s DATA port with a modular cable.
(The control data and alarm signal will be output from
the unit to the recorder.)
5. After the connection, set the unit’s EXT IN to GENLOCK
ON through SETUP MENU or WJ-SX150A Administrator
Console (Refer to pp. 71 or 97).
Notes:
• You need WJ-HD500A or a newer model for the maxi-
mum-rate recording.
• The playback, multiscreen output or live images from the
recorder are not displayed on Monitor 1 to 4. To confirm
the images, you need to connect another monitor with
the recorder.
• The recorder will not operate if its unit address is set to
other than 1.
• Make sure the recorder’s unit address is set to 1
through SETUP MENU or WJ-SX150A Administrator
Console. (Refer to pp. 71 or 97.) If another number is
selected, you cannot control the recorder.
Matrix Switcher
Recorder
16
16
15
15
14
14
13
13
12
12
11
11
10
10
9
9
8
8
7
7
6
6
5
5
4
4
3 2
2
3
1
1
SIGNAL GND
10/100BASE-T
SPOT
OUT
IN EXT STORAGE COPY
CONTROL ALARM
VIDEO
MODE
DATA
REMOTE(WV-CU50)
GEN-LOCK OUT
SERIAL
IN
OUT
OUT
MULTI SCREEN OUT
AUDIO
EXT IN
GENLOCK
OUT
MULTI
SCREEN
OUT
DATA
DATA HDR
Monitor
CAMERA
1
1
2
2
3
3
2
DATA 3 DATA 2
SERIALALARM
TERM
OFF ON
4
2
1
4
3
EXT OUT
(REC OUT)
CAMERA
SW IN
RS485(CAMERA)
LINE
SELECT
MONITOR OUT
EXT IN
(PLAY IN)
OUT
IN
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
RS485(CAMERA)PS•DATA
DATA 4DATA HDR DATA 1
• Make sure the recorder’s unit address is set to 1
through SETUP MENU or WJ-SX150A Administrator
Console. (Refer to pp. 71 or 97.) If another number is
selected, you cannot control the recorder.