68
Notes:
• MODE and LCN(PRE/TOUR) cannot be selected by
pressing the numeric buttons. Press the NEXT or PREV
button for selection.
• PRE doesn’t appear when TOUR 1 to 16 is selected for
MODE.
• When selecting a camera without the preset position
function, select "- -" for PRE.
• When moving the joystick to ▼ at the bottom of ALARM
EVENT 1 of 10, the monitor will display 2 of 10 (the next
page).
• When moving the joystick to ▲ at the top of ALARM
EVENT 2 of 10, the monitor will display 1 of 10 (the pre-
vious page).
• Each ALARM PORT can be assigned to only one alarm
number. If you enter the same ALARM PORT more than
one time, the newer will be activated and the older will
be changed to a space.
• An alarm event will be activated even if the selected
logical camera number is not assigned to any camera
channel.
In this case, black image and “NOT ASSIGN” will be
displayed on the monitor.
• Set the parameter of a port number area by pressing
the numeric button(s).
• If you press the NEXT or PREV button at a port pin num-
ber area, the parameter will be switched among a
space and ALARM PORT not assigned to other alarm
events.
After the configuration, press the MON (ESC) button. The
monitor display returns to ALARM SETUP.
• ALARM INPUT
430 CAMERA
This stands for that an alarm input is accepted via the
CAMERA IN connectors or the RS-485 ports.
ON: The alarm-associated sequence/spot image is dis-
played on a monitor, and alarm recording will start
(if a recorder is connected to the unit).
REC ONLY: Only alarm recording will start and moni-
tors will keep displaying the current sequence/spot
images.
Note: You cannot recover alarm-related operations
from system controllers when REC ONLY is
selected.
OFF: An alarm input is accepted neither via the CAM-
ERA IN connectors nor the RS-485 ports.
The factory default setting is OFF.
440 ALARM PORT
This stands for that an alarm input is accepted via the
ALARM port (25-pin D-sub connector at the rear panel).
ON: The alarm-associated sequence/spot image is dis-
played on a monitor, and alarm recording will start
(if a recorder is connected to the unit.)
ALM: This stands for the alarm event number.
MON: This stands for the monitor number.
MODE: This stands for the preset position of a camera
or tour sequence number activated with an alarm
input signal.
• LCN(PRE)/TOUR: Activates a spot camera or tour
sequence with an alarm input. To activate a spot
camera, select LCN nn (nn is a logical camera num-
ber: 01 to 99). To activate a tour sequence, select
TUR nn (nn is a tour number: 01 to 32).
When you selected a combination camera for LCN
nn, enter the desired preset position number. PRE
01 to 64 is available. When you selected another
type of camera, select “-“.
REC: This stands for a recorder activated with an alarm
input signal. If no recorder is activated, the parame-
ter will be a space. The REC area displays the num-
ber of recorder which receives images from a cam-
era whose logical camera number is correspondent
with the alarm event number.
R0 to R4 shows the following.
Recorder number Recorder
R0 Master recorder
R1 Slave 1 recorder
R2 Slave 2 recorder
R3 Slave 3 recorder
R4 Slave 4 recorder
420 ALARM EVENT 2 of 10
ALM MON MODE REC ALARM PORT
LCN(PRE)/TOUR
11 1 LCN 11
/
PRE01 R0 MASTER
/
11
12 1 LCN 12
/
PRE01 R0 MASTER
/
12
13 1 LCN 13
/
PRE01 R0 MASTER
/
13
14 1 LCN 14
/
PRE01 R0 MASTER
/
14
15 1 LCN 15
/
PRE01 R0 MASTER
/
15
16 1 LCN 16
/
PRE01 R0 MASTER
/
16
17 1 LCN 17
/
PRE01 R2 SLAVE1
/
1
18 1 LCN 18
/
PRE01 R2 SLAVE1
/
2
19 1 LCN 19
/
PRE01 R2 SLAVE1
/
3
20 1 LCN 20
/
PRE01 R2 SLAVE1
/
4
LCN:LOGICAL CAMERA NUMBER
420 ALARM EVENT 10 of 10
ALM MON MODE REC ALARM PORT
LCN(PRE)/TOUR
91 1 LCN 91
/
PRE01
92 1 LCN 92
/
PRE01
93 1 LCN 93
/
PRE01
94 1 LCN 94
/
PRE01
95 1 LCN 95
/
PRE01
96 1 LCN 96
/
PRE01
97 1 LCN 97
/
PRE01
98 1 LCN 98
/
PRE01
99 1 LCN 99
/
PRE01
LCN:LOGICAL CAMERA NUMBER
Note: If a WJ-HD200 Series recorder is connected to
CAM 1 to 8, recorder number will be displayed
even camera channels (CAM 9 to 16) not connect-
ed to the recorder.
ALARM PORT: When an alarm port pin set here
receives an input signal, the designated event is
activated. MASTER, SLAVE 1 to 4 is available for
the matrix switcher. 1 to 16 is available for the alarm
port number. To deactivate the alarm number,
press the button 0. ALARM PORT will be a space.
The factory default setting is same as the illustrations.