Panasonic WJ-SX150A Switch User Manual


 
15
SLAVE DOWN (Displayed when communication is not
established between the Master and Slave units: for
example, power/cable disconnection)
* n is a number.
Notes:
When pressing the associated numeric button (1 to 5)
while holding down the OSD button, information is
turned on or off.
When you select the LCN (logical camera number) not
assigned in the system, NOT ASSIGN will appear
beside the camera number.
The Display Position
The display position of the information is adjustable with the
joystick on the system controller.
Priority Lock
Priority lock is the function to prevent other operators' con-
trol of a monitor even after the system log-out.
While the priority lock is active, the monitor is operable by
the locking operator and higher-priority operators.
Sequence Mode
Camera images are displayed for a fixed time, and they are
sequentially switched.
The change from a tour sequence into the spot mode is
also possible.
Before use, the parameters of the sequence, such as a
camera or monitor selection and dwell time need to be con-
figured.
There are two sequences:
Tour sequence
Group sequence
Tour Sequence
The images through Camera 1 to 99 are displayed on a
given monitor in the desired sequence.
A tour sequence is consisted of 64 steps and up to 32
sequences are configurable.
Up to 30 seconds are selectable as each step's dwell time.
Each step can call the desired preset position of a camera
to be displayed.
Monitor-related Functions
The following functions related to monitors are configurable.
Monitor Selection
It is necessary to select a monitor when controlling the
monitor-related functions, such as camera images or
SETUP MENU.
Information Displayed on the
Monitors
The following information is displayed on monitors.
Time and Date
Time and date are displayed.
The date display is selectable from five patterns, and the
time display is selectable from 24- or 12- hour system.
The date display pattern (Example: August 21, 2001)
21/08/2001
08/21/2001
21/Aug/2001
2001/08/21
Aug/21/2001
Camera Title
The camera number (C01 to C99) and characters (up to 20)
can be configured as a camera title.
The title is displayed in one line.
Monitor Status
The following status is displayed in one line.
Mn (Monitor number)*
Kn (Controller number)*
Tnn (Monitor mode: the example shows the tour
sequence)*
Rn (Recorder number)*
* "n" is a number.
Event
The information related to system operation is displayed.
An alarm control, alarm suspension, and timer event are the
example.
ALARMnn (The alarm is operating.)
ALARMnn ACK (The alarm has been acknowledged.)
Tnn (Timer event: tour sequence number)
LOSS CHnn (the video loss channel number)
ALM SUSPENDED (The alarm is suspended.)
CAM SW LOSS Rn* (Displayed when no camera switch-
ing pulse is supplied from Rn)
08/21/2001 6:50:08 PM
M1 K1 T01
C01 camera title ALARM10*
Clock
Monitor status
Camera title
Event
CH1 CH2
CH3