Parameters
Operator Number
This box displays a list of registered operators.
1-6: These are operator numbers who are registered as
the factory default setting. Operator Number 1 can-
not be deleted.
Timer: This operator is used for the priority change of a
timer event. When the timer event's priority is higher
than that of an operator, the event is valid. When an
operator's priority is higher than that of a timer
event, the event is invalid. This operator cannot be
deleted.
Add Operator Number
This drop-down menu is used for the new operator number
selection. 7 to 16 can be added.
Operator Group
This group configures each operator's password, level and
priority.
ID: Enter an operator's ID. From 1 to 99999 are avail-
able.
Password: Enter a password. From 1 to 99999 are
available.
Level: Select 1, 2 or 3. Refer to Level Table for details
on level setting.
Priority: Select the operator's priority from 1 (highest)
to 16 (lowest).
Camera Access Group
This group configures the camera operation coverage of
each operator.
Click on each camera's checkboxes and determine the
available operation.
1 (View & Control): The operator can display the cam-
era image on the monitor and control panning/tilt-
ing.
2 (View Only): The operator can display the camera
image on the monitor, but cannot control the pan-
ning/tilting.
3 (Prohibited): The operator can neither display the
camera image on the monitor nor control the pan-
ning/tilting.
(Add) button
Adds a new operator to WJ-SX150A.
(Edit) button
The registered parameters become editable by clicking on
this button after selecting the operator number.
(Delete) button
Deletes an operator from WJ-SX150A after you select the
operator.
(OK) button
Saves the configuration and closes the Operator
Registration window.
Level Table
This window configures the restrict level of each operation.
The restrict level is classified in Level 1, 2, and 3.
How to Display
To display this window, click on the (Level Table) but-
ton in the main window (p. 80).
Parameters
Permission
Click on each checkbox to classify the following operations
by three levels.
SX150A Setup: Setting up this matrix switcher system
Camera Setup: Setting up the cameras
Program Preset Position: Registering a camera's pre-
set position
Camera Control: Controlling a camera
Camera Selection: Selecting a camera
Recorder Setup: Displaying the recorder's setup menu
Recorder Control: Controlling the recorder
All Alarm Reset: Resetting all the alarms
Single Alarm Reset: Resetting an alarm
Alarm Suspend: Suspending an alarm
Call Sequence: Activating a tour or group sequence
Alarm History Display: Displaying the alarm history
Video Loss History Display: Displaying the video loss
history
System Status Display: Displaying the system status
OSD Control: Controlling on-screen display (Time and
date, monitor status, camera title, and event)
(Save Exit) button:
Saves the configuration and closes the Level Table window.
(EXIT) button
Cancels the configuration and closes the Level Table win-
dow.