96
Note: The new character has not been saved in the
configuration data at this point. After closing the
Edit Font window, be sure to return to the Camera
Title window and click on the (Save Exit) but-
ton.
• To Copy a Character
1. Click on the desired character in the User Font box.
2. Click on the Copy button.
3. Click on the blank in the User Font box to copy the
character.
4. Click the Paste button.
• To Delete a Character
1. Click on the desired character in the User Font box.
2. Click on the Delete button.
3. Click on the Save –> button.
■ Data Port
This window configures the parameters of each data port
(RS485, DATA 1 to 4 and DATA HDR port): the protocol, the
baud rate (communication speed), and the connected
cameras.
● How to Display
To display this window, click on the (Data Port) button
in the main window (p. 80).
● Parameters (Normal Connection)
• Protocol
Select “Camera” when an RS-485 camera is connected to
the data port. Select “Terminal_K1 to 4” when the system
controller is connected to the data port.
Select PS·Data when the system controller is connected to
the DATA 4 port via the PS·Data protocol. PS·Data mode
will appear in the window.
Notes:
• The baud rate of DATA HDR is the same as that of PSD.
When you select PSD for DATA 4, DATA HDR and its
baud rate are displayed in gray and not configurable.
When you select CU360C for DATA 4, DATA HDR and
its baud rate are configurable.
• Terminal_K1 to 4 can be assigned to only one port.
• Baud Rate
Select the desired baud rate (communication speed). 4800,
9600 or 19200 bps is selectable.
• Cam 1 to 16
Select the camera(s) connected to the RS-485 daisy chain.
Data 1 to 3 are connectable to either of cameras and sys-
tem controllers.
When connecting cameras to these ports, select the con-
nected camera number(s).
• PS·Data mode
This stands for the PS·Data parameters of the DATA 4 port.
Logout Time: Select the desired operable time before
logout. OFF, 30, 60, 90 or 120 sec is available.
The factory default setting is 30 sec.
Note: Select OFF when only PS·Data system
controllers are connected.
Alarm Data: Select the desired time to accept an alarm
input signal. OFF, 0, 1 or 5 sec is available.
The factory default setting is 1 sec.
Wait Time: Select the desired wait time to transmit an
alarm output signal. OFF, 100msec, 200m sec,
400m sec or 1 sec is available.
The factory default setting is OFF.
Group Address: This parameter is only for confirma-
tion. Leave as it is.
• Fixed Common Parameter Group
The data bit (8 bit), parity (none), and stop bit (1 bit) are
displayed. These parameters are fixed.
● Parameters (Master)
DATA 3 is used for master-slave connection. Protocol is
fixed to Master-Slave and Baud Rate is fixed to 38400.
Note: Other parameters are same as normal connection.