Port
75
740 CAMERA/DATA1-4 PORT
SWITCHER=MASTER(5 of 5)
PORT MODE SPEED
CAMERA TERMINAL-K1 9600bps
DATA1 TERMINAL-K2 9600bps
DATA2 TERMINAL-K3 9600bps
DATA3 MASTER-SLAVE 38400bps
DATA4 PS-DATA 9600bps
HDR HDR 9600bps
SERIAL PC 38400bps
Master unit setting for Master-Slave connection
Slave unit setting for Master-Slave connection
SWITCHER: Select a unit (SLAVE1 to 4 and MASTER*) to
configure the parameters.
* In normal connection, only MASTER is displayed.
The factory default setting is same as the illustration.
PORT: This stands for the type of a port.
CAMERA: RS-485 Camera port
DATA 1/2/3/4: DATA 1/2/3/4 ports
HDR: DATA HDR port
SERIAL: SERIAL port
MODE: This stands for the operation mode of a port.
CAMERA: Select this if a camera is connected.
TERMINAL-K1/K2/K3/K4: Select this if a terminal-mode
system controller is connected.
PS·DATA: Select this if a PS·DATA system controller is
connected.
MASTER-SLAVE: The port used for the master-slave
connection is fixed to this parameter.
HDR: The HDR port is fixed to this parameter.
PC: WJ-SX150A Administrator Console configuration
and firmware update becomes available with a PC
connection.
VCR: Select this if a time-lapse VCR (Panasonic model)
is connected.
– – –: This port is unusable.
The following are MODE parameters assigned to
each port.
740 CAMERA/DATA1-4 PORT
SWITCHER=SLAVE1(1 of 5)
PORT MODE SPEED
CAMERA CAMERA 19200bps
DATA1 CAMERA 19200bps
DATA2 CAMERA 19200bps
DATA3 CAMERA 19200bps
DATA4 MASTER-SLAVE 38400bps
HDR HDR 9600bps
SERIAL -- 38400bps
The factory default setting is same as the illustration.
SPEED: This stands for the communication speed of a port.
38400 bps*: Select this to set the speed to 38400 bps.
19200 bps: Select this to set the speed to 19200 bps.
9600 bps: Select this to set the speed to 9600 bps.
4800 bps: Select this to set the speed to 4800 bps.
* This parameter is available only for SERIAL.
The factory default setting is same as the illustration.
Notes:
• If the DATA 4 is set to PS·DATA, SPEED of PS·DATA will
be changed in conjunction with that of HDR.
• When you change MODE, the default communication
speed is automatically set. The SERIAL port is set to the
default speed when CONTROL is changed in 600
RECORDER. (Refer to p. 71.)
The default communication speeds are shown in the dia-
gram.
MODE Factory default setting
CAMERA 19200 bps
TERMINAL 9600 bps
PS·DATA 9600 bps
HDR 9600 bps
PC 38400 bps
VCR (VTR) 9600 bps
CAMERA
DATA 1
DATA 2
DATA 3
DATA 4
HDR
SERIAL
Master
Normal connection
CAMERA
TERMINAL-K1/K2/
K3/K4
CAMERA
TERMINAL-K1/K2/
K3/K4
CAMERA
TERMINAL-K1/K2/
K3/K4
CAMERA
TERMINAL-K1/K2/
K3/K4
PS
·
DATA
HDR
PC
Master-slave connection
TERMINAL-K1/K2/
K3/K4
CAMERA
TERMINAL-K1/K2/
K3/K4
CAMERA
TERMINAL-K1/K2/
K3/K4
CAMERA
MASTER-SLAVE
TERMINAL-K1/K2/
K3/K4
PS
·
DATA
HDR
PC
Slave 1
to 4
CAMERA
CAMERA
CAMERA
CAMERA
MASTER-
SLAVE
HDR
– – –
VCR VCR VCR