77
■ MULTIPLEXER
● How to Display
To display this menu on the monitor, move the cursor to 900
MULTIPLEXER in SETUP MENU by moving the joystick to
D or C. Then, press the CAM (SET) button. The submenu
appears on the monitor.
● Parameters
Move the joystick to move the cursor.
Press the NEXT or PREV button to select the desired para-
meters.
SWITCHER: Select a unit (SLAVE1 to 4 and MASTER*) to
configure the parameters.
* In normal connection, only MASTER is displayed.
Ver. ∗. ∗∗: Firmware version of a Multiplexer board
• ALARM
EXT.: Select this to gen-lock the unit with the recorder
when an alarm is input to the unit.
002,004 to 128 (field): Select one of these alarm
recording rates if the asynchronous unit is connect-
ed to the unit.
The factory default setting is EXT.
MUX
• CAM 01 to 16:
These stand for an operator's camera operation coverage.
The following are the parameters.
VIEW & CONTROL: The operator can display the cam-
era image on the monitor and control panning/tilt-
ing.
VIEW ONLY: The operator can display the camera
image on the monitor, but cannot control the pan-
ning/tilting.
PROHIBITED: The operator can neither display the
camera image on the monitor nor control the pan-
ning/tilting.
The following is the factory default setting of this menu.
Note: When you enter an invalid number, the parameter will
return to the state before your numerical entry.
6
OPERATOR NO. ID PASSWORD LEVEL PRIORITY
1 150 150 1 1
2 1 12345 1 2
3 100 100 1 3
4 101 101 1 4
5 102 102 2 5
6 103
103 3
CAM 1 to 16 = VIEW & CONTROL (for OPERATOR NO. 1 to
6)
900 MULTIPLEXER
SWITCHER=SLAVE1(1 of 5) Ver.∗.∗∗
VCR REC MODE
910 ALARM EXT.
920 NORMAL EXT.
930 DYNAMIC REC OFF
940 DUMMY BLACK ON
950 CAM SW LOSS ON
900 MULTIPLEXER
SWITCHER=MASTER(5 of 5) Ver.∗.∗∗
VCR REC MODE
910 ALARM ---
920 NORMAL ---
930 DYNAMIC REC ---
940 DUMMY BLACK ---
950 CAM SW LOSS ---