Paradyne 3800PLUS Modem User Manual


 
COMSPHERE 3800Plus Modems
9-6 November 1996 3980-A2-GB30-20
As data banks are transferred, the local and remote
LCD’
s bottom line displays the status of the download
process, and the number of records sent versus the total
number of records for that bank.
F1
RemClone
OK
Call_Setup
F2
F3
If
the download is successful, the local modem
displays
Remote Clone OK and the remote modem
displays
Frmware Upgrade. If the download took place
over the dial network, the modems disconnect when the
download is complete.
If unsuccessful,
RemClone Failed
is displayed on the
LCD’s top line. Attempt another download from the local
modem. If this fails, contact your service representative.
To Local via DTE
This function is for use only by customer service
personnel to transfer new firmware to 3800Plus
modems.
Automatic Firmware
Download
New
releases may be available for the 3800
Plus
modem. The latest 3800Plus firmware is available at no
charge from the Automatic Firmware Download Center.
Refer to page A in the front of this document for contact
information.
To download the firmware, your modem must be
configured for dialing. Save your modem’s current
configuration to the Customer 1 or Customer 2 memory
area, and load the Async Dial factory template. (See
Chapter 8, Configur
e Branch
, for information about
saving and changing configuration options.)
If you have a DTE (a terminal or PC) attached to your
modem, informational messages are displayed on it when
the modem is connected. These show the amount of time
the download will take.
However, a DTE is not required. The download begins
without any operator action. When the download begins,
the DCP displays download status messages with the data
bank number, current block being loaded, and the total
number of blocks. There are two data banks.
F1
Download Status
Bank 1:0088/0092
F2
F3
If
the modem connects at 14,400 bps, the download
takes about 10 minutes. When the download is complete,
the modem resets itself and displays a normal status
message (such as
Idle:28.8).
Reload your configuration options from the
Customer 1 or Customer 2 memory area that you saved
them to.
Download Failure
If the download is interrupted, the modem is left in a
state in which it can only be used to make or receive a call
for a download.
F1
DownldOnly Mode>
Call_Setup
F2
F3
If an interruption occurs and your modem is left in this
state, repeat the download process by directing the modem
to dial the Automatic Firmware Download Center. (See
Chapter 5,
Call Setup Branch
, for information about
dialing a number using the DCP.) If you are unable to
complete the download, call your service representative
for assistance.