Paradyne 3800PLUS Modem User Manual


 
Remote Branch
10-33980-A2-GB30-20 November 1996
The Top-Level menu of the remote 3800Plus
modem is
similar to the local 3800Plus modem with the following
exceptions:
Change Directory is the only function available
under the Call Setup branch.
Self and Local Analog Loop do not appear under
the T
est branch when using the secondary channel.
When using the primary channel, the T
est branch
does not appear
.
In the Control branch, Make Busy is not available.
The Security Branch is not available.
Exit Remote replaces Remote on the local modem’s
LCD.
To return to local modem operation, select ExitRem.
Any changes made to configuration options while using
the Remote branch are not saved until you exit the
Remote branch.
The following conditions can cause Remote branch
access to fail:
The local modem is not able to communicate
with the remote modem because of a poor dial
network or leased-line connection, or the remote
modem is not a COMSPHERE (3800, 3900, or
3800Plus
series) modem. If this is the case, the
status message
No Response
appears on the LCD.
If a connection is established but the remote
modem’s Access from Remote configuration option
is disabled, then the status message
Access
Disabled appears on the LCD.
If a connection is established but the wrong
password is stored, the status message
Password
Invalid appears on the LCD. This configuration
option must be enabled by the remote user. (See
Remote Access Password configuration option in
Chapter 8, Configur
e Branch
.)