AT Command Set and S-Registers
13-253980-A2-GB30-20 November 1996
Table 13-2
(12 of 13)
3800
Plus
S-Registers
AT Command Front Panel BranchDescription
S88 Straps When Disconnected
Register determines whether the Active(Operating) area is reloaded upon
a disconnect.
Register has the following values:
0 (or 231)=No Change
1 (or 232)=Reload
2 (or 233)=Reload with no AT Change
The factory default templates do not affect S88.
Configure\Edit\Misc
S89 V.42 ARQ Window Size Increase
Register allows the V.42 Automatic Request for Transmission (ARQ)
window size to be set to a value from 6 to 15 frames to accommodate
satellite delays.
Register has the following values:
0=6 frames (default)
1=7 frames
2=8 frames
3=9 frames
S
S
S
S
9=15 frames
This command applies only to connections made using V.42bis data
compression or V.42 error control.
Factory setting is 6 frames.
None
S90 DTE Rate=VF Rate
Register forces the DTE (computer) data rate to be equal to the VF
(telephone line) data rate.
Register has the following values:
0=Disable
1=Enable
Factory setting is Disable.
Configure\Edit\
DTE Interface
S91 Cellular Enhancements
Register determines whether parameters are set to improve performance
over a cellular link. Should be enabled when the remote modem is using a
cellular connection.
Register has the following values:
0=Disable
1=Enable
Factory setting is Disable.
Configure\Edit\
V42/MNP/Buffer