Paradyne 3800PLUS Modem User Manual


 
Test Branch
7-53980-A2-GB30-20 November 1996
Loc Digital Loop
Loc
Digital Loop is issued by a local modem and
forces it to loopback any data received from the remote
modem (Figure 7-3). (This test operates the same as a
CCITT V.54 Loop 2 except it is issued at your modem.)
This is useful if a remote modem is incapable of initiating
a remote digital loopback from its location. For this test to
operate properly
, the modems must be online and in
Synchronous or Asynchronous Direct mode and, if set for
V.34 modulation, must not be in Asymmetric Rate mode.
To access Loc Digital Loop from the T
est branch, make
the following selections:
F1
Test :
Loc_Digital_Loop
F2
F3
Press the key until Loc Digital Loop appears. Press
any function key to start this test.
F1
Test : Digitl Loop
Started
F2
F3
The
message
Started appears on the LCD and the Test
LED lights.
If the message
Invalid Command
appears on the
LCD, then another test is in progress. Select Abort to clear
the current test and then select Loc Digital Loop.
If the Test Timeout configuration option is enabled,
Test Timeout appears at the conclusion of the LCD. If it is
disabled, the test operates until aborted. For more
information on the Test Timeout configuration option,
refer to the Tests
section in Chapter 7.
To exit this function and remain in the T
est branch,
press the
key
. To exit and return to the Top-Level
menu, press the
key
.
AT Command Equivalent
The
A
T command for Local Digital Loopback is &T3.
Figure 7-3. Local Digital Loopback