Paradyne 3810 Network Card User Manual


 
Security
12-53810-A2-GB30-20 November 1996
Set Access Ctrl
Set
Access Control allows you to change security
configuration. This function is protected by an
Administrative Password. The Reset Security function
allows you to reset the Administrative Password, but
results in erasure of the modem’
s security database.
To access Security from the Top-Level menu, make the
following selections:
F1
Idle : 19.2
Control Security
F2
F3
Press the key until Security appears. Select Security.
Set Access Control allows you to configure critical
parameters contained within the security database table
that control dial access security
. These parameters are
protected by an Administrative Password, which is an
8-digit decimal number.
Set Access Control contains the Edit Password T
able,
Set Answer Security, Set Originate Security, and Set
Administrative Password security configuration groups.
These groups do not appear on the LCD until the correct
Administrative Password is entered.
Administrative Password
The Administrative Password is an 8-digit decimal
number password that allows only authorized users to
access Security branch functionality
. This password must
be entered every time you access the Security branch.
This feature is shipped from the factory with the
Administrative Password set to 00000000.
Once the correct Administrative Password is entered,
the Edit Password Table, Set Answer Security, Set
Originate Security, and Set Administrative Password
groups can be displayed on the LCD.
To enter your Administrative Password from
Set_Access_Ctrl, make the following selections:
F1
Security >
Set_Access_Ctrl
F2
F3
Select Set_Access_Ctrl from the Security branch.
F1
Admin Password?
Entą
Ą
"00000000
F2
F3
The
Administrative Password appears. This occurs
every time you enter the Security branch.
Select the F2 ("
) key to increment password values.
Press the
key to move the cursor to the next
position.
Continue this sequence until the full Administrative
Password value appears and then press Ent.
F1
Set Access Ctrl >
Edit PassWd Table
F2
F3
If the correct value is entered, the EditPassWdTable
group appears on the LCD.
Press the
key to scroll the Set Answer Security, Set
Originate Security, and Set Administrative Password
groups into view.
If an incorrect administrative password is entered, then
the message
PassWrd Invalid
appears as well as the last
password entered. Enter the correct password value or
press the
or key to exit the Security branch.