Paradyne 3810 Network Card User Manual


 
Test Branch
8-73810-A2-GB30-20 November 1996
Figure 8-6. End-to-End Pattern Test
To access Pattern from the T
est branch, make the
following selections:
F1
Test : >
Pattern
F2
F3
Press the key until Pattern appears. Select Pattern
to start this test.
F1
Test : Pattern >
Blks Errd = xxxxxxx
F2
F3
BlksErrd=xxxxxxx displays the number of blocks of
data found in error (block size is 1000 bits per block). The
message
NoSync can appear as a value for BlksErrd while
the modem’
s receiver is synchronizing. The message
OvrFlw can appear as the value for BlksErrd if the
counter overflows.
Press the
key to display
BlksRcvd=xxxxxxx,
number of blocks of data received.
The Pattern test can be exited and reentered without
restarting the test. The BlksErrd and BlksRcvd continue
counting.
If the Test Timeout configuration option is enabled,
T
est T
imeout appears at the conclusion of the test. If it is
disabled, the test operates until aborted. For more
information on the Test Timeout configuration option,
refer to the Tests section of Chapter 9.
To exit this function and remain in the T
est branch,
press the
key
. To exit and return to the Top-Level
menu, press the
key
.
AT Command Equivalent
The
A
T command for Pattern is &T2.