Paradyne 3810 Network Card User Manual


 
COMSPHERE 3800 Series Modems
8-4 November 1996 3810-A2-GB30-20
Rem Digital Loop
Rem Digital Loop performs a remote digital loopback
(CCITT V.54 Loop 2), Figure 8-2. This test can verify the
integrity of the local modem, the communications link,
and the remote modem. Any data or pattern entered at the
local DTE is sent to and returned from the remote modem.
For this test to operate properly
, the modems must be
online and in Synchronous or Asynchronous Direct mode.
To access Rem Digital Loop from the T
est branch,
make the following selections:
F1
Test :
Rem_Digital_Loop
F2
F3
Press the key until Rem_Digital_Loop appears.
Press any function key to start this test.
F1
Test : Remote Loop
Started
F2
F3
The
message
Started appears on the LCD, and the Test
LED (Model 3810 and Model 3811) lights for the duration
of the test.
If the Test Timeout configuration option is enabled,
T
est T
imeout appears at the conclusion of the test. If it is
disabled, the test operates until aborted. For more
information on the Test Timeout configuration option,
refer to the Tests
section in Chapter 9.
To exit this function and remain in the T
est branch,
press the
key
. To exit and return to the Top-Level
menu, press the
key
.
AT Command Equivalent
The
A
T command for Remote Loopback is &T6.
Figure 8-2. Remote Digital Loopback