Paradyne 3810 Network Card User Manual


 
COMSPHERE 3800 Series Modems
14-16 November 1996 3810-A2-GB30-20
Table 14-2
(1 of 11)
3800 Series S-Registers
S-Register
Description Front Panel Branch
S0 Auto-Answer Ring Number
Register determines number of rings the modem will count before
automatically answering a call.
Enter zero (0) if you do not want the modem to automatically answer any
calls. Otherwise, enter a value from 1 to 255 for the number of rings to
count before answering.
Factory setting is 1.
Configure\Edit\Line Dialer
S2 AT Escape Character
Register determines ASCII value used for escape sequence to enter
Command mode from Data mode.
Enter a value from 1 to 127 for the escape character. Any value greater
than 127 causes the modem to disable the escape sequence. When the
escape sequence is disabled, the modem cannot return to Command
mode until the call is disconnected.
Factory setting is 43 (+ key).
Configure\Edit\DTE Dialer
S3 Carriage Return Character
Register determines ASCII value used as the carriage return (Return
key). This character is used to end command lines and result codes.
Enter a value from 0 to 127 for the command end character.
Factory setting is 13 (carriage return key).
NOTE: The &W command used to save this change must be on a
separate line. This ensures both that the change is intentional,
and that the DTE can enter the new character.
Configure\Edit\DTE Dialer
S4 Line Feed Character
Register determines ASCII value used as the line feed character.
Enter a value from 0 to 127 for the line feed character.
Factory setting is 10 (ASCII carriage return or line feed).
Configure\Edit\DTE Dialer
S5 Backspace Character
Register determines ASCII value used as the backspace (Backspace
key). This character moves the cursor to the left and erases the previous
character.
Enter a value from 0 to 127.
Factory setting is 08 (backspace key).
Configure\Edit\DTE Dialer
S6 Blind Dial Pause
Register determines how long (in seconds) the modem waits after going
off-hook before dialing a telephone number if using result code X0, X1,
or X3.
Enter a value from 2 to 255 seconds.
Factory setting is 2 seconds.
Configure\Edit\Line Dialer
S7 No Answer Timeout
Register determines how long (in seconds) an originating modem waits
before abandoning a call when no answer tone is received.
Enter a value from 1 to 255 seconds.
Factory setting is 45 seconds.
Configure\Edit\Line Dialer