10. Setting Up Network Health for FrameSaver Device
10-4 December 2002 9700-A2-GB20-20
Configuring the Discovered Elements
Network Health sets the speed for discovered elements when it polls the device for
the first time. For a FrameSaver device, the speed set would be the unit’s CIR. No
additional configuration should be required, but verify that all appropriate
information has been retrieved.
NOTE:
If a FrameSaver device does not have CIR configured, or if it is not configured
correctly, Network Health sets the unit’s CIR to 0 Kbps. For this reason, you
should reconfigure the unit’s CIR before Network Health polls it. If 0 Kbps is
the speed setting, you will need to edit the unit’s CIR from Network Health.
See
Discovering Elements
in the
Network Health User Guide
for additional
information, configuration and editing.
Procedure
To change the FrameSaver device’s CIR unit elements from Network Health:
1. Select the Edit Before Saving button at the bottom of the Discovering dialog
box once the discovery process is completed.
The Poller Configuration window opens.
2. Double-click on the first element discovered. The Modify Element dialog box
opens.
3. In the Speed box, select the Override radio button and enter the device’s CIR
in the text box.
Letters k and m can be used as shortcuts (e.g., enter 56 k for 56 Kbps, or
16 m for 16 Mbps.
4. Apply your changes:
— Select the Apply/Next button to save your change and bring up the next
element to be edited. Continue until all newly discovered frame relay
elements have been modified before selecting the OK button.
— Select the OK button.
The Modify Element dialog box closes.
5. Select the OK button at the bottom of the Poller Configuration window. The
modified elements are saved to the database, and the devices are polled.
Allow Network Health to continue polling for about a half an hour to allow time for