2. User and Command Line Interfaces, and Basic Operation
9700-A2-GB20-20 December 2002 2-5
Screen Work Areas
There are two user work areas:
Screen area – Where you input information or information is displayed.
Function keys area – Where you perform specific screen functions.
Screen Area
Function Keys Area
Menu Path
Device Name
Message Area
main/config/system/slv 9783-C-SLV
Device Name: Node A 05/13/2002 23:32
SERVICE LEVEL VERIFICATION SYSTEM OPTIONS
SLV Sample Interval (secs): 60
SLV Synchronization Role: Tributary
SLV Type: Standard
SLV Delivery Ratio: Disable
DLCI Down on SLV Timeout: Enable
SLV Timeout Error Event Threshold: 3
SLV Timeout Clearing Event Threshold: 1
SLV Round Trip Latency Error Threshold (ms): 10000
SLV Latency Clearing Event Threshold: 2
SLV Packet Size (bytes): 64
-------------------------------------------------------------------------------
Ctrl-a to access these functions, ESC for previous menu MainMenu Exit
Save
Date and Time
Model Number
Screen Format Description
Menu Path Menu selections made to reach the current screen.
Device Name Customer-assigned name for the FrameSaver device.
Model Number:
Feature Set 1
9783-C – Central site CSU/DSU that supports 64 PVCs.
9720, 9783, 9788 – Remote site CSU/DSU that supports 8 PVCs.
9783-Rtr, 9788-Rtr – Router that supports 8 PVCs.
Model Number:
Advanced SLM
Feature Set
9783-C-SLV – Central site CSU/DSU that supports 64 PVCs and
has the Advanced SLM Feature Set installed.
9720-SLV, 9783-SLV, 9788-SLV – Remote site CSU/DSU that
supports 8 PVCs and has the Advanced SLM Feature Set
installed.
9783-RtrSLV, 9788-RtrSLV – Router that supports 8 PVCs and
has the Advanced SLM Feature Set installed.
Screen Area Fields for configuring and monitoring the FrameSaver device.
Function Keys
Area
Specific functions that can be performed by pressing a specified key,
then pressing Enter.
Message Area
System-related information and valid settings for input fields in the
lower left corner.
System and Test Status messages in the lower right corner.