Q-Logic 59060-02 B Switch User Manual


 
59060-02 B 3-1
Section 3
Event Messages
This section lists event messages from the command line interface and Enterprise
Fabric Suite 2007 in message ID sequence by the following severity levels:
Alarm Events
Critical Events
Warning Events
Informative Events
You can look up a message by its message ID or by searching for the message
text. If the message you are looking for does not appear in this section, contact
your authorized maintenance provider.
3.1
Alarm Events
(A1000.000F) (The switch is canceling the hotreset - try again later)
Meaning: You cannot move forward with the hot reset. All applications and
switch resources are backing out of the procedure and returning to
normal operation.
Action: Ensure that the fabric is stable and that no changes are being
made to switch configurations or connections and try again.
(A1000.001D) (Hotreset failed and the switch must be reset normally)
Meaning: The hot reset has failed and left the switch in an indeterminate
state.
Action: Reset the switch.
(A1000.001E) (Hotreset failed and the switch is being reset)
Meaning: There was a failure during the hotreset process, the switch is being
reset normally.
Action: None.