3 – Event Messages
Alarm Events
3-22 59060-02 B
S
(A1007.0006) (Security: Could not validate Authentication Response from port_number,
payload seems to be incorrect.)
Meaning: The format of the payload of the response frame does not match
what was expected.
Action: Check for errors on the remote side of the link. Check the
transceiver and cable. Update firmware on remote switch.
(A1007.0007) (Security: Fabric Binding (ESA) not supported on remote switch and Fabric
Binding is enabled, failing security checks)
Meaning: Either fabric binding is not enabled on the remote switch or the
remote switch does not support security at all.
Action: Check the security configuration on the remote switch.
(A1007.0008) (Security: ESA Response failure, failing security checks)
Meaning: A failure was received during processing of the ESA received
frame. Either the payload did not match the standard layout or the
payload status indicated a reject.
Action: Check for errors on the remote side of the link. Check the
transceiver and cable. Update firmware on remote switch.
(A1007.0009) (Security checks EFMD response failure, failing security check.)
Meaning: A remote switch rejected a EFMD frame. The port will be isolated.
Action: Check remote switch for the reason that the EFMD frame was
rejected. It is possible that the FabricBindingEnabled parameter is
different on the two switches.
(A1007.000A) (Security: Dropping lock held by domain domain_id for number seconds)
Meaning: A remote switch has held the fabric lock for too long. Local switch
is dropping the lock in order to send out a Exchange Fabric
Membership Data (EFMD) frame.
Action: None.
(A1007.000B) (Security: EFMD Rejected, bad revision)
Meaning: The remote switch is running at a different Exchange Fabric
Membership Data (EFMD) version level than the local switch. Ports
will isolate.
Action: None