3 – Event Messages
Alarm Events
59060-02 B 3-31
A
(A3004.0001) (Non-fatal hardware error detected. Use 'show post log' for more info)
Meaning: A non-fatal hardware error was discovered during the
Power-On-Self-Test (POST) phase of startup.
Action: Enter the Show Post Log command to investigate.
(A3004.0002) (Diagnostics have detected a partial failure on the I/O blade in slot
slot_number)
Meaning: Diagnostic testing has determined that there is a partial failure on
specified I/O blade. Most likely, at least one of the ports did not
pass the Power-On-Self-Test (POST).
Action: Enter the Show Post Log command to investigate.
(A3008.0000) (The configuration area was damaged or a Remake Filesystem was
performed from PROM mode. You must perform a 'config restore' to clear
this error.)
Meaning: The configuration area was damaged or a Remake Filesystem was
performed from Maintenance mode.
Action: Enter the Config Restore command to clear the error. If this does
not correct the problem, contact your authorized maintenance
provider.
(A3014.0001) (Blade in slot slot_number set Down due to failure of all AuxPorts)
Meaning: The blade in the named slot has isolated because all auxiliary ports
to the cross-connect blades have failed.
Action: Contact your authorized maintenance provider.
(A3014.0002) (Blade in slot slot_number set Online due to internal failure recovery)
Meaning: The blade in the named slot has recovered at least one auxiliary
port to a cross-connect blade and is no longer isolated.
Action: None
(A3014.0003) (Blade blade_ID set Down due to blade type mismatch)
Meaning: The I/O blade given by blade_ID has isolated because the
operational blade type does not match the configured blade type.
Action: Change the configured blade type to match the I/O blade that is
present, or insert an I/O blade of the configured blade type.
(A4000.0001) (threshold of value hit rising trigger trigger_number in value second window on
port port_number - ALARM SET
Meaning: The switch exceeded the specified threshold rising trigger in the
specified sample window.
Action: Investigate the specified port for problems or adjust the rising
trigger or sample window.