3 – Event Messages
Alarm Events
3-30 59060-02 B
S
(A3000.0002) (Temp sensor sensor_name on blade slot_number reads value C - ALARM
SET)
Meaning: The chassis temperature has reached a failure threshold.
Action: Check air flow, fan operation, and ambient temperature. If the
problem cannot be corrected, power down the switch.
(A3001.0001) (Temp overwarm, sensor_name sensor reads value C - ALARM SET)
Meaning: The chassis temperature has reached a warning threshold.
Action: Check air flow, fan operation, and ambient temperature.
(A3002.0001) (sensor name sensor has returned to normal range - ALARM CLEARED)
Meaning: The chassis temperature has returned to the normal range and the
alarm condition has been cleared.
Action: None
(A3002.0002) (Temp sensor sensor_name on blade slot_number reads value C - ALARM
CLEARED)
Meaning: The named blade has returned to the normal operating
temperature range.
Action: None.
(A3003.0001) (Fatal hardware error detected. The switch is not operational. Use 'show
post log' for more info)
Meaning: A fatal hardware error was discovered during the
Power-On-Self-Test (POST) phase of startup. This switch is not
currently operational.
Action: Enter the Show Post Log command to investigate.
(A3003.0002) (POST detected a fatal error the last time it ran. The switch is not
operational. Use 'show post log' for more info)
Meaning: A fatal hardware error was discovered from the previous
Power-On-Self-Test (POST). This switch is not currently
operational.
Action: Enter the Show Post Log command to investigate.
(A3003.0003) (Diagnostics have detected a fatal error on the I/O blade in slot slot_number.
The blade is not operational.)
Meaning: Diagnostic testing has determined that there is a failure on
specified I/O blade. The blade did not pass the Power-On-Self-Test
(POST).
Action: Enter the Show Post Log command to investigate.