3 – Event Messages
Alarm Events
59060-02 B 3-19
A
(A1005.0022) (Blade in slot slot_number must be reset after leaving Diagnostics
AdminState)
Meaning: After changing the switch administrative state from Diagnostics to
any other state, the blade must be reset to complete the state
change.
Action: Reset the blade.
(A1005.0024) (Switch must be reset after leaving the Diagnostics Admin State)
Meaning: After changing the switch administrative state from Diagnostics to
any other state, the switch must be reset to complete the state
change.
Action: Reset the switch.
(A1005.0034) (System resource error - contact technical support)
Meaning: There is a system resources problem on the switch.
Action: Contact technical support.
(A1005.0035) (System resource error - contact technical support)
Meaning: There is an internal problem on the switch.
Action: Contact technical support.
(A1005.0036) (Hotswap procedure failed before last reset - must hardreset switch)
Meaning: The blade hotswap procedure failed and the switch was reset
without a power-on self test.
Meaning: Reset the switch with a hard reset.
(A1005.0037) (Hotswap procedure never completed - the blade will not be functional until
the switch is hardreset)
Meaning: The blade hot-swap procedure was not completed.
Action: Reset the switch with a hard reset.
(A1005.0038) (Switch incompatibility error - contact technical support)
Meaning: Switch incompatibility error.
Action: Contact technical support.
(A1005.0039) (Fabric Login (FLOGI) from address FC_address failed)
Meaning: The payload of the FLOGI was not valid.
Action: Check device connection or replace the device. If the problem
persists, contact your authorized maintenance provider.