3 – Event Messages
Informative Events
3-44 59060-02 B
S
(W) (8700.000A) (EPort) (Port: port_number) (No response from remote switch, resetting
Inter-Switch Link (ISL))
Meaning: No communication has been received from the remote switch for
some time indicating that it may not be functioning properly. The
E_Port will be reset in an attempt to reestablish the ISL.
(W) (8F00.000C) (Fabric Status status)
Meaning: The severity of the fabric status has changed. The description field
will show the reason for fabric status.
(W) (8F00.000D) (Switch Status status)
Meaning: The severity of the switch status has changed. The description field
will show the reason for the switch status.
(W) (8F00:000E) (Link Status status)
Meaning: The severity of the link status has changed. The description field
will show the reason for link status.
3.4
Informative Events
(I) (8200.0001) (mserver) (Hotreset is not permitted at this time, try again later)
Meaning: The switch was busy at the time of the attempted hot reset. Try the
hot reset again later.
(I) (8200.0002) (mserver) (Port: port_number) (Rejecting request from address FC_address,
inband management is disabled on port port_number)
Meaning: A Management Server command was received on a port that is
configured to be disabled for inband management requests.
(I) (8200.0100) (mserver) (Cannot map number_of_characters characters to Switch
Symbolic Name (max number_of_characters))
Meaning: The RIELN management server command was processed, and the
Interconnect Element Logical Name was registered. However, the
registered name is of greater length than the maximum length
allowed for the Switch Symbolic Name, so therefore the Switch
Symbolic Name was not changed to match the registered name.
(I) (8200.0101) (mserver) (Cannot map non-printable characters to Switch Symbolic Name)
Meaning: The RIELN management server command was processed, and the
Interconnect Element Logical Name was registered. However, the
registered name contains unprintable characters. These characters
are not allowed for the switch symbolic name, therefore the switch
symbolic name was not changed to match the registered name.