3 – Event Messages
Alarm Events
3-4 59060-02 B
S
(A1003.001D) (Failing remote zoning configuration, total zones in zonesets limit would be
exceeded)
Meaning: The maximum number of zones in zone sets has been exceeded
on the switch as a result of a zone merge.
Action: Reduce the number zones on the remote switch.
(A1003.001F) (Failing remote zoning configuration, member limit for zone zone_name
exceeded, (size= number_of_zones, limit= maximum_number_of_zones))
Meaning: The maximum number of members for the given zone has been
exceeded as a result of a zone merge.
Action: Reduce the number of members in the given zone on the remote
switch.
(A1003.0020) (Failing remote zoning configuration, total zone limit would be exceeded)
Meaning: The maximum number of zones has been exceeded on the switch
as a result of a zone merge.
Action: Reduce the number of zones on the remote switch.
(A1003.0021) (Failing remote zoning configuration, Zoneset is empty)
Meaning: An empty zone set was included as part of a zone merge and was
rejected.
Action: Modify the zoning database on the remote switch to remove or
correct the empty zone set.
(A1003.0022) (Unable to update database with newly activated information, a 'save'
operation is in progress)
Meaning: Modifications were being made to the security or zoning database
while a security set or zone set was being activated or deactivated
from a remote switch.
Action: Avoid activating or deactivating a security set or a zone set while
changes are being made anywhere in the fabric.
(A1003.0023) (Fabric Busy Zoneset operation failed)
Meaning: The activation or deactivation of a zone set failed because the
fabric is currently busy.
Action: Try the activation or deactivation again later.
(A1003.0024) (Request already in progress (internal lock held))
Meaning: A fabric operation is currently in progress.
Action: Wait and try again.