Q-Logic 59060-02 B Switch User Manual


 
3 – Event Messages
Alarm Events
3-14 59060-02 B
S
(A1004.0023) (Attempting to connect to switch with incompatible time out value
configured (R_A_TOV/E_D_TOV).)
Meaning: An E_Port isolated because the values for R_A_TOV or E_D_TOV
are not the same on both switches.
Action: Modify the switches so that the time out values are the same.
(A1004.0024) (Attempting to connect to switch that is in non-interop mode)
Meaning: An attempt was made to connect to a switch with a different value
for Interop Mode.
Action: Modify the Interop Mode values so that they are the same on both
switches.
(A1004.0026) (Configured Domain ID domain_ID not available and Domain ID is locked on
this switch)
Meaning: An attempt was made to connect a switch to a fabric with a
conflicting domain ID and the domain ID could not be reassigned.
Action: Change the domain ID so that it is unique in the fabric or disable
the domain ID lock so that the domain ID can be automatically
reassigned.
(A1004.0029) (No Switch capable of being Principal Switch. Reconfigure Principal Switch
Priority.)
Meaning: An E_Port isolated because the principal priority on all switches is
set to 254.
Action: Configure one of the switches to be the principal switch by
changing the principal priority.
(A1004.002B) (Port port_number not configured for E-Port capability, reconfigure to G/GL
to connect to remote switch)
Meaning: An attempt was made by a remote switch to connect through a port
that could not configure itself as an E_Port.
Action: Change the port type on the remote switch to G_Port or GL_Port.
(A1004.002D) (Non-interop Legacy switch setting prevents domain/port zoning)
Meaning: Zone members involving switches of other vendors cannot be
defined by domain ID and port number when Interop Mode is
disabled and Legacy Address Formatting is enabled.
Action: Disable (False) the Legacy Address Formatting, enable Interop
Mode, or reassign the zone members using a method other than
domain ID and port number.