Page 6-7
Section 6. Replacement Procedures
SATO CL608e/CL612e Service Manual
PN 9001079
Rev. B
6.3 Replacing the Fuses
Fuse replacement is described in the following section.
· 6.3.1 Removing and Replacing the Main Power Fuse
· 6.3.2 Removing and Replacing the Internal Fuse
6.3.1 Removing and Replacing the Main Power Fuse
NOTE: Before replacing a fuse, determine
the cause of the overload condition.
Required: F3A, 250V Fuse Fuse
STEP PROCEDURE
1. Switch the printer OFF and disconnect the power cable.
2. Locate the fuse cap on the back of the printer. Unscrew the cap and
remove the defective fuse. Fig. 6-6
3. Replace the fuse with one of equal rating (3A, 250V). Do not use a
fuse with a higher rating.
4. Screw the fuse cap back and connect the power cable.
BACK OF PRINTER
FUSE (UNDER COVER)
Fig. 6-6