SATO CL608e/CL612e Printer User Manual


 
Page 2-37
Section 2. Configuration
SATO CL608e/CL612e Service Manual
PN 9001079
Rev. B
LCD Panel — Clear Non-Standard Protocol
To Clear Non-Standard protocol codes, place DSW2-7 in the ON position and power on
the printer while simultaneously pressing the LINE and FEED keys.
Alt. Protocol
Default Complete
STEP PROCEDURE
1. When the printer emits one long beep release the LINE and FEED keys.
2. When the keys are released, the printer will replace the Alternate protocol
codes with the default values.
3. After the default setting is complete, the printer will emit three short beeps
indicating that the process is complete.
To exit the mode, power the printer off, then back on.
The standard protocol codes used by the printer can be modified to accomodate the
requirements of different host systems. However, if the printer is to be used with a
system that does not use the custom protocol codes, they can be cleared and the default
protocol codes reactivated.
The default values are:
STX = 7B
H,
ETX = 7D
H,
ESC = 5E
H,
ENQ = 40
H,
NULL = 7E
H,
CAN = 21
H
and OFFLINE = 5D
H.
Download User Defined Protocol Codes
The user can define a set of custom protocol codes and download them to the printer
using the <ESC>LD command.
To enter the User Download mode, place DSW2-7 in the ON position and power on the
printer while simultaneously pressing the LINE key. When the printer emits one long beep
release the LINE key.
User Download
Press the Line Key
STEP PROCEDURE
1. Set DSW2-7 to the OFF position to replace the Standard protocol codes
or ON to replace the Alternate set of protocol codes.
2. Press the LINE key. The printer is now waiting for the data to be sent.
user download
waiting
alt protocol
default complete
initializing
rom v00.00.00.00
initializing
rom v00.00.00.00
user download
press the line key