PN 9001079
Rev. B
Page 1-6
SATO CL608e/CL612e Service Manual
Section 1. Overview and Specifications
Operation Panel/Displays
POTENTIOMETERS
VR1 (Print) To adjust print darkness (fine adjustment).
VR2 (Offset) To adjust amount of back/forward feed for dispenser/cutter/tear-off
bar position (+/- 3.75).
VR3 (Pitch) To adjust home print position of the label (+/- 3.75 mm).
VR4 (Display) To adjust the contrast of the LCD display.
*DSW2 & DSW3 Dip Switches used to set operational
parameters of printer. Refer to Section
2 for settings.
*NOTE: Optional RS232 Communication Card contains DSW1 switches which
are configured when supplied with the printer.