Page 9-2
Section 9. Optional Accessories
SATO CL608e/CL612e Service Manual
PN 9001079
Rev. B
9.2 Label Cutter Kit Installation
STEP PROCEDURE
1. Turn the printer OFF and disconnect the AC power cord.
2. Remove (3) screws holding the left side cover to the printer. Raise the access
door and loosen the (2) screws on the inside top of the printer. Lift off the left
side cover. Figs. 9-1
3. Remove the ribbon and label stock if installed.
4. Remove the front cover from the printer by removing 5 screws. Figs. 9-2
5. Remove (2) screws and discard bracket. Fig. 9-3
6. Place the cutter unit face down and identify the two sets of cables with cables
marked CUTP & CUTS.
Refer to Fig.9-4. Detach cable and install new cable at same locations.
7. Route the opposite end of cable connectors from the cutter through the access
hole in the print engine and through the hole in the aluminum side plate.
Figs. 9-5
8. Refer to Figs. 9-6. Detach the SEN3 connector from the printer PCB and save.
Replace with cable connector marked CUTS from the cutter and cable
connector marked CUTP from the cutter to CN2 connector on the power supply.
Be sure all cables are properly routed.
9. Secure the cutter unit to the front of the printer using (5) screws provided.
Figs. 9-7
10. Reinstall the printers side cover and close the lid.
11. Set dip switches on bank three, marked DSW3: 1=ON and 2=OFF. The dip
switches are located on the front panel below the line and feed keys.
12. Connect the power cord to the printer. The installation of the cutter is now
complete.
The Cutter is a field installable option. No critical adjustments or special tools are
required.