Tally Genicom 6600 Printer User Manual


 
AIAG Forms
109
Predefined Forms
Code V comes with the following two predefined forms already stored in
permanent memory:
AIAG form
Preliminary Metals form
The barcode portions of these predefined forms can be printed at either 120
DPI high density or 60 DPI low density. However, the Halfdot Mode reduces
print speed by approximately 50% during the printing of the barcode(s).
The predefined forms reside in the printer ROM. If a predefined form is used,
it is copied from ROM into the Heap Buffer RAM. The amount of RAM being
used ca be determined by executing the IFORM,L command. If the amount of
the RAM becomes insufficient for the creation of new forms, the predefined
forms can be deleted from RAM similar to user-defined forms using
^IFORM,D or ^IFORM,R.
AIAG Forms
The AIAG (Automotive Industry Action Group) form is a cretion of automotive
industry that utilizes both barcode and human-readable characters to create a
standardized label for shipping and identification. The CVCC contains high
density and low density versions of the AIAG form in ROM. The names of
these forms are:
AIAG_H.MT for low density.
AIAG_F.MT for high density.
The following rules apply when using the AIAG forms:
1. If one of the data fields is not completely filled with data, the remaining
characers for that field must end with ^-, ^*, or ^+.
2. If the data field requires both a human-readable field and a barcode field,
the same value must be sent for both fields.