Tally Genicom 6600 Printer User Manual


 
124
Chapter 7 Control Sequences
Valid Control Sequences
The following eleven control sequences are valid in Barcode/Block Character
Mode:
^A Move the Home.
^B Select Horizontal Barcode.
^C Select Vertical Barcode.
^D Select Double Density Block Characters.
^M Select Normal Density Block Characters.
^N Select New Introducer.
^R Relative Cursor Move.
^S Signed Cursor Move.
^T Absolute Cursor Move.
^U Set Unit Line.
^W Set Barcode Density.
^A - Move The Home
Moves the Home pointer and homes the cursor.
Command ^A(home)NL
Arguments
(home) The distance to move the Home pointer down in
increments of 0.01 inches. Default is the current
vertical position.
^B - Select Horizontal Barcode
Selects horizontal barcode and sets barcode parameters.
Command ^B(type);(height);(size);(option)NL
Arguments
^B Selects Horizontal Barcode Command.
(type) The style of Barcode (default = 1).
1 = Code 39
2 = Code 39 with Check Digit added.
3-5 = Not used.
6 = Two of five with 2:1 Ratio.
7 = Interleaved Two of Five with 2:1 Ratio.
8-9 = Not used.
10 = Two of Five with 3:1 Ratio.
11 = Interleaved Two of Five with 3:1 Ratio.
12 = UPC Version A, 10 Data Digits
13 = EAN-13
14 = EAN-8
(height) Height of the individual bars in increments of 0.01
inches, ranging from 1 - 255 (default = 80).