Tally Genicom 6600 Printer User Manual


 
130
Chapter 7 Barcodes
Barcodes
Barcodes can be printed either vertically or horizontally from 01 to 2.55 inches
high. The Barcode styles can now be defined individually.
Code 39 (Types 1 And 2)
Character Set
0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z - .
(space) $ / + %
Data Limits
No limits are imposed by your printer. However, Barcode readers are typically
limited to 32 characters.
Check Digits
No limits for Type 1. Type 2 encodes one check digit at the end of the
character string.
Emulation Limitations
Your printer does not support the full ASCII character set in this emulation. If a
character outside of the specified character set is received, it is encoded as a
solid black character. It is possible to encode the character pair representation
of all characters in the full ASCII set (see
Tab le 6). For example, if your reader
is in the full ASCII Mode, a lower-case “a” may be encoded by using +A (see
Tab le 6, top of column 4). Any of the lower-case letters may be represented
by a “+” followed by the corresponding letter.
Table 6. Code 39 Character Print Equivalents, ASCII Code 39
NUL %U (space) (space) @ %V %W
SOH $A ! /A A A a +A
STX $B /B B B b +B
ETX $C # /C C C c +C
EOT $D $ $ D D d +D
ENQ $E % % E E e +E
ACK $F & /F F F f +F
BEL $G /G G G g +G
BS $H ( /H H H h +H
HT $| ) /I I I i +I