Telect MIX 56 Network Card User Manual


 
1 Descriptions MIX 56 User Manual
1-2 Telect, Inc. 122188-10 A0
Features
DSX and M13 in one chassis
Two fully independent systems per chassis, each with 28 DSX jacks
and up to two M13 cards, in a 5.25 inch (3 RU) rack space
Mounts in 19 inch (48.3 cm) or 23 inch (58.4 cm) WECO-spaced or
EIA-spaced racks
Multiplexes 28 DS1 or 21 E1 signals into one DS3 signal and demulti-
plexes a DS3 signal into 28 DS1 or 21 E1 signals
1:1 redundancy with second M13 card
Processor switching occurs in less than 50 ms
LED status indicators and tracer lamps on front panel
DSX jacks, tracer lamps, and alarm boards are field replaceable and
M13 cards are hot-swappable, all from the front of the chassis
Form-C critical, major, and minor external alarm contacts
Remote provisioning and monitoring through SNMP or two concurrent
Telnet sessions
Separate alarm and event logs are rotating logs of up to 99 entries each
Selectable alarm thresholds
DS1 and DS3 loopback capabilities
•BER Testing
DS3 signal format selectable between C-bit or M13 mode
C-Bit Remote Control to the MIX 56 at the other end of the DS3 link
DS1 line coding individually selectable between AMI or B8ZS for T1
and AMI or HDB3 for E1
Adjustable DS1 transmit line build out (LBO) for each channel
Automatic DS3 LBO
DS3 transmit clock source either recovered from DS3 receive signal or
by internal oscillator
Universal voltages: 20Vdc to 60Vdc
Three levels of user login security
Part Numbers
Part No. Configuration
747-0000-2448 56 DSX Jacks, No M13 Cards
747-1103-2801 56 DSX Jacks, Two M13 Cards
747-1103-5601 56 DSX Jacks, Four M13 Cards