MIX 56 User Manual 4 Software Operation
122188-10 A0 Telect, Inc.
4-41
Step Action
1. From the Directory screen, press 16 to select Current Alarms, then
Enter.
The Current Alarms screen appears:
2. Tab to “Card Select” and press the spacebar to toggle between “Ac-
tive” and “Standby”. Press Enter.
3. To view the next 14 entries, tab to [Next] and press Enter.
4. To view the previous 14 entries, tab to [Previous] and press Enter.
5. To engage or disengage the ACO, tab to the button below the Time
Remaining field and press Enter. If the ACO is engaged, the button
that appears is [Disengage ACO]. If the ACO is disengaged, the
button that appears is [Engage ACO].
To View the Alarm Log
You can view a history of alarms in the Alarm Log, a screen that displays
the last 99 alarm entries. An entry is made in the Alarm Log when an alarm
is triggered, and again when it is cleared.
Each page in the Alarm Log contains up to11 entries that show the date and
time each alarm started or ended, the type of alarm, and a detailed explana-
tion of the alarm. You can move forward or backward through the pages,
and when finished viewing alarms, you can clear the entire log.
MIX 56 by Telect system 2 Directory (Ctrl+D)
Help (?)
Current Alarms - Active
----------------------- Alarm Cutoff: Disengaged
Card Select: Active Time Remaining: 00:00
[Engage ACO]
Alarm Details Start Date / Time
----- ---------------------------------------------------- ------------------
Crt multiple low speed failures 22/Oct/03 07:37:35
Mjr LS-02(Low Speed 02),LOS 22/Oct/03 07:37:35
Mjr LS-03(Low Speed 03),LOS 22/Oct/03 07:15:02
Mjr LS-01(Low Speed 01),Rx AIS 22/Oct/03 07:14:49
Mjr 15 min. ES LS threshold crossed 22/Oct/03 07:16:04
Mjr 15 min. SES LS threshold crossed 22/Oct/03 07:14:56
Mjr 24 hr. ES LS threshold crossed 22/Oct/03 07:29:59
Mjr 24 hr. SES LS threshold crossed 22/Oct/03 07:29:59
Mnr backup power B failed 22/Oct/03 07:13:00